Info
- Certificated by American Bureau of Shipping (ABS), Bureau Veritas (BV), Lloyd’s Register, RINA
Application
Marine cable with rated voltage 250V for control and instrumentation. For installation in ships according to IEC60092-376
Regulations | General Properties
- According to construction standards IEC 60092-376
- Flame retardant according to IEC60332-1-2
- Fire retardant according to IEC60332-3-22
- Halide content according to IEC60754-1
- PH and conductivity according to IEC60754-2
- Fluorine content according to IEC60684-2
- Smoke density according to IEC61034-1 y IEC61034-2
Construction
- Copper wire conductor, Class 2, according to UNE 60228
- Cross-linked polyethylene (XLPE) insulation (thickness according to IEC60092-376 Chart 2)
- Colour identification: black with white numbering or blue and black numbering
- Braided in pairs
- Pair shield made of aluminum mylar + flexible tinned copper drain wire
- Outer sheath type SHF1 according to IEC60092-359 (thickness according to IEC60092-376 – 14.1)
- Grey or orange colour
- Outer diameter according to IEC60092-350 Annex D
Specifications
- Temperature range in fixed installation –40º a 90ºC
- Maximum temperature in case of short-circuit 250ºC for 5 minutes.
- Minimum temperature during installation –15ºC
- Rated voltage 150/250V
- Test voltage 1.500V
- Electrical resistance according to UNE 60228