Info
- Highly flexible cable, with easy routing and installation and time and installation cost reduction
- Certificated by American Bureau of Shipping (ABS), Bureau Veritas (BV), Lloyd’s Register, RINA
- Also available in the Marineline PZ1 version with copper conductor Class 2.
Application
Flexible fire resistant marine cable with rated voltage 0.6/1kV for power and control. For installation in ships according to IEC60092-353
Regulations | General Properties
- According to construction standards IEC60092-353
- Flame retardant according to IEC60332-1-2
- Fire retardant according to IEC60332-3-22
- Halide content according to IEC60754-1
- pH and conductivity according to IEC60754-2
- Fluorine content according to IEC60684-2
- Smoke density according to IEC61034-1 y IEC61034-2
- Fire resistant according to IEC60331-21, IEC60331-31
Construction
- Flexible copper wire conductor, Class 5, according to UNE 60228
- Fireproof barrier made of mica tape
- Cross-linked polyethylene (XLPE) insulation (thickness according to IEC60092-353-1 Chart 1)
- Colour identification according to HD308 (with or without yellow-green)
- Outer sheath type SHF1 according to IEC60092-359 (thickness according to IEC60092-353 – 3.7.3)
- Black colour
- Outer diameter according to IEC60092-350 Annex D
Specifications
- Rated temperature in fixed installation –40º a 90ºC
- Maximum temperature in case of short-circuit 250ºC for 5 minutes.
- Minimum temperature during installation –15ºC
- Rated voltage 0.6/1kV
- Test voltage 4,000V
- Electrical resistance according to UNE 60228