Sumline RE-2X(ST)YSWAY TiMF Sumline RE-2X(ST)YSWAY TiMF
RoHS CompliantOil ResistantHydrocarbon ResistantFlame RetardantFire RetardantSunlight ResistantMoisture ResistantMechanical ResistanceChemical resistantFixed installation

Info

  • For indoor and outdoor environments, in cabinets, conduits or trays, and buried directly.
  • Resistant to UV rays, flame retardant and resistant to hydrocarbons, with excellent mechanical protection.
  • Compliant with CE low voltage regulations and free of hazardous substances according to RoHS.

Application

Instrumentation cable with general shielding, in metal armoring and suitable for installation in industrial plants.

Regulations | General Properties

  • Construction standard EN 50288-7
  • Flame retardant according to IEC 60332-1
  • UV resistant according to UL 1581
  • Oil and hydrocarbon resistant according to ICEA S 73-532

Construction

  • Polished copper conductor, semi-rigid Class 2 (Sumline) or flexible Class 5 (Sumflex), according to EN 60228
  • Cross-link polyethylene insulation (XLPE 90ºC)
  • Numbered black and white conductor identification (other colours available upon request)
  • Wiring by triads with optimal braid spacing to block interferences
  • Individual electromagnetic protection shielding, with Alu/Mylar tape, surrounding each triad (TiMF)
  • Plastic tape protection surrounding the cables
  • Electromagnetic protection shielding, Alu/Mylar tape, surrounding the set and with a 50% minimum overlapping
  • Tin plated copper shielding continuity wire, 7 thin wires
  • Plastic tape protection under seating
  • Special PVC inner seat, flame retardant and resistant to hydrocarbons
  • Galvanised steel wire armoring, minimum coverage of 90%
  • Special PVC outer sheath, flame retardant, UV and hydrocarbon resistant
  • Available in black, grey or blue (Intrinsic safety)

Specifications

  • Service temperature -30ºC to +90ºC
  • Minimum curve radius 12 x external cable diameter
  • Insulation resistance 5000 M? x km
  • Mutual capacitance <150 nF/km
  • Inductance 1 mH/km
  • Service voltage (and voltage test) 300V (1kV) or 500V (2kV)

Contact


In accordance with the regulations in force in the Personal Data Protection, we inform you that your data will be incorporated into the processing system owned by SUMCAB SPECIALCABLE GROUP SL with Company Tax No. B61787131 and registered office at GRAN BRETANYA, 29 08520, FRANQUESES DEL VALLES, LES (BARCELONA), in order to answer your questions and send you related information that may be of interest. In compliance with current regulations, SUMCAB SPECIALCABLE GROUP SL states that data will be kept for the period strictly necessary to comply with the aforementioned precepts. Until you tell us otherwise, we will understand that your data has not been modified, that you agree to notify us of any variation and that we have your consent to it for the purposes mentioned. SUMCAB SPECIALCABLE GROUP SL informs that it will proceed to treat the data in a lawful, faithful, transparent, adequate, pertinent, limited, exact and updated manner. SUMCAB SPECIALCABLE GROUP SL therefore undertakes to adopt all reasonable measures so that these are suppressed or rectified without delay when they are inaccurate. In accordance with the rights conferred by the current regulations on data protection, you may exercise the rights of access, rectification, limitation of treatment, deletion, portability and opposition to the processing of your personal data and consent provided during its handling, by sending your request to the postal address indicated above or to the email OSCAR@SUMCAB.COM OSCAR@SUMCAB.COM. In turn, we inform you that you can contact the Data Protection Delegate of SUMCAB SPECIALCABLE GROUP SL, by writing to the e-mail address dpo.cliente@conversia.es or calling 902877192. You can contact the relevant Supervisory Authority with your complaint. By sending the data collection form, you agree to accept the privacy policy of SUMCAB SPECIALCABLE GROUP SL.