Info
- Fire-resistant instrumentation cable for use on industrial offshore platforms.
Application
Collectively shielded armoured cables for installation in control circuits on platforms, with special characteristics, namely non-fire propagation, fire resistance and reduced emission of opaque smoke, toxic and corrosive gases. Halogen-free, resistant to oil and mud
Regulations | General Properties
- Construction regulations NEK TS 606
- Fire retardant, IEC 60332-3-22 CAT A
- Fire resistant according to IEC 60331
- Halogen-free Low acidity and gas corrosivity IEC 60754
- Low opaque smoke emissions IEC 61034-2
Construction
- Class 2 tinned copper conductor
- HEPR insulation according to IEC 60092-351 + mica tape
- Black and light blue numbered conductor identification
- Polyester tape on the cabling
- General copper/polyester screen + drain wire
- Inner halogen-free cover
- Tinned copper braid armour
- Crossed external cover, halogen-free and mud resistant (SHF2 Mud)
Specifications
- Operating voltage: 150/250V
- Test voltage: 1,5 kV
- Minimum operating temperature: -40 °C
- Maximum operating temperature: 90 °C
- Bend radius: 8 x cable diameter