- Space saving by means of its extra-thin insulation wall
- Compliance with standard EN50306-4.
- Compliance with the standards regarding fire tests in trains: DIN5510-2; NF F 16-101; UNI CEI 11170-3.
Application
Flexible shielded multiconductor command and control cable suitable for installation inside trains
Regulations | General Properties
- According to construction standards EN50306-4
- Vertical flame spread according to EN60332-1-2; NF C 032-070, 2.1
- Vertical flame spread, arranged in groups, according to EN50266-2-4; EN50266-2-5; EN50305, 9.1.2; NF C 032-070, 2.2
- Smoke density according to EN61034-2; X10-702-2
- Toxicity according to EN50305, 9.2
- Corrosivity of combustion gases according to EN50267-2-2
Construction
- Tinned electrolytic copper, Class 5 flexibility according to EN60228
- Special polymer insulation 1
- Conductor identification: white with numbering or yellow/green
- Stranding in concentric layers
- Special polymer outer sheath
- Black colour
Specifications
- Rated voltage 300V/500V AC – 450V DC
- Temperature range –40ºC to +120ºC